Load cells specially designed to measure the tension force applied to a running cable or running rope.
o Custommade design according to your needs
type of rope (steel, synthetic, optical fiber, umbilical)
capacity
rope diameter (from 6 up to 115 mm)
maximum winding speed
accuracy
Material
load pin stainless steel
other nickelplated steel or stainless steel (option)
o Complete range of CE certified electronics and load limitation devices available
Reference:5570-5575
Protection class:IP65
Cable length:6 m (other lengths available on request)
Reference temperature (°C):23
Compensated temperature range (°C):-10...+45
Service temperature range (°C):-25...+70
Storage temperature range (°C):-50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1
Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1
Nominal sensitivity (mV/V):± 1
Input resistance (ohm(s)):350 ± 2
Output resistance (ohm(s)):350 ± 2
Insulation resistance (50 V) (Mohm(s)):> 5000
Reference excitation voltage (VDC):10
Permissible nominal range of excitation voltage (VDC):3...12
Safe load limit (% F.S.*):200
Breaking load (% F.S.*):> 300
Permissible dynamic loading (% F.S.*):70
Les formations sont des activités de groupes déterminés de durée courte à moyenne, destinées à découvrir/approfondir ensemble des compétences ou thématiques. Le travail en commun favorise la création et le renforcement de la culture d'entreprise.
Load cells specially designed to measure the tension force applied to a running wire rope. The removable center sheave enables easy installation without cutting the winch lines.
o Wide range of cables (Ø from 6 up to 115 mm)
other components stainless steel (5580)
other components nickelplated steel (5585)
o Complete range of CE certified electronics and load limitation devices available
o Custommade manufacturing
Reference:5580 - 5585
Protection class:IP67
Cable length:6 m (other lengths available on request)
Reference temperature (°C):23
Compensated temperature range (°C):-10...+45
Service temperature range (°C):-25...+70
Storage temperature range (°C):-50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1
Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1
Nominal sensitivity (mV/V):± 1
Input resistance (ohm(s)):350 ± 2
Output resistance (ohm(s)):350 ± 2
Insulation resistance (50 V) (Mohm(s)):> 5000
Reference excitation voltage (VDC):10
Permissible nominal range of excitation voltage (VDC):3...12
Safe load limit (% F.S.*):200
Breaking load (% F.S.*):> 300
Permissible dynamic loading (% F.S.*):70