• According to DIN EN 61810-1, DIN EN 60664-1
• Different pin configurations and pin arrangements
• Clearance and creepage distances:
contact-coil ≥ 8 mm
• Compact size, small height (horizontal model)
• OA 5651, 5661 horizontal models
• OA 5652, 5662, 5692 vertical models
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:8 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,8 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:28 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661
CANopen
Integrierter 1Q Regler
Integrierte Leistungselektronik
DC Permanentmagnetmotor
Absolute Positionserfassung (multiturn)
Lebensdauer: 2.000 h
Isolierstoffklasse: B, optional F
Schutzart: IP 42, optional bis IP 65
Umgebungstemperatur: -15°...40°C
Caratteristica
— Motori CC a magnete permanente
— Spazzole in grafite e rame
— Carcassa del motore zincata
— Cuscinetti a sfera
— Fori di montaggio secondo le norme DIN 42016
Dati generali
— Durata appros.: 3000 h
— Carico max sullalbero: assiale 40 N
— Carico max sullalbero: radiale 100 N
— Classe d'isolamento: DIN VDE 0530, E
— Classe di protezione: DIN VDE 0530, IP 40
— Soppressione RFI: fattibile
AC/DC:DC
Tipo:sincrono
Tensione:10 V...50 V,5V
Altre caratteristiche:a magneti permanenti
LED Outdoor Laufschrift mit einer Auflösung von 32*224 Pixel bei einem Pixelpitch von 10mm. Die Ansteuerung erfolgt per Software via Ethernet-Schnittstelle.
Anwendungsbereich:outdoor
Schrifthöhe:4-zeilig: 65mm // 2-zeilig: 160mm // 1-zeilig: 310mm
LED Farbe:Blau
Ansteuerung:Ethernet
Integrating sphere detector for Laser power in W.
Features: 50 mm dia, 10 mm dia port, synthetic ODM98 coating, 400 nm - 1100 nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate
• According to DIN EN 61810-1, DIN EN 60664-1
• Low rated power consumption
• 2 changeover contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
• Adjustment to customers specification
• Compact size, small height (at horizontal model)
• OA 5661.12 horizontal mounting
• OA 5662.12 vertical mounting
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:6 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,4 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 70 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:37 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661.12
• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching safety because of gold plated double contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• Voltage range 0.75 ... 1.2 UN
• 15.5 mm height
Function:Safety relays with double contacts
Type of relay:monostabil
Contact material:AgNi + 5 µm Au
Continuous current:5 A
Nominal voltage UN DC:6 - 110 V
Voltage Range UN:0,75 - 1,2 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:5,5 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT III (wash-tight)
Size L x W x H:46,5 x 22 x 15,5 mm
Approvals:TÜV; cRUus
Relay type:OA 5621_D