• According to DIN EN 61810-1, DIN EN 60664-1
• Different pin configurations and pin arrangements
• Clearance and creepage distances:
contact-coil ≥ 8 mm
• Compact size, small height (horizontal model)
• OA 5651, 5661 horizontal models
• OA 5652, 5662, 5692 vertical models
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:8 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,8 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:28 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661
CANopen
Integrierter 1Q Regler
Integrierte Leistungselektronik
DC Permanentmagnetmotor
Absolute Positionserfassung (multiturn)
Lebensdauer: 2.000 h
Isolierstoffklasse: B, optional F
Schutzart: IP 42, optional bis IP 65
Umgebungstemperatur: -15°...40°C
Axial-Querstromgebläse
Noch bessere Anlagerung - weniger Abdrift und Spritzmittelverlust durch gezielte Luftführung. Daher umweltfreundlicher und effektiver.
Top-Serienausrüstung
- mech. Bedieneinheit mit Bowdenzügen
- Saugfilter mit Absperrautomatik
- Druckfilter mit Schnellreinigung
- Behälterfüllstandsanzeige
- Hydr. Rührwerk
- Spülbehälter zur Systemreinigung
- Handwaschbehälter 15 l
- Behälterauslaufhahn
- Gebläse abschaltbar
- Myers-Einzeldüsen mit Tropf-Stop schwenk- und abstellbar (außerhalb vom Luftstrom).
Düseneinsätze Albuz gelb
- Teleskop Gelenkwelle Walterscheid
- Einseitige Abdeckung zu D 36A - für hohe Kulturen
Zusatzausrüstung
- Myers-Doppel- und Dreifachdüse
- Düseneinsätze nach Wahl
- Magnetventile
Einsatzbereich
- Reihenabstand: 1,6 bis 8,0 Meter
- Kultur-Höhe: bis 12,0 Meter
• According to DIN EN 61810-1, DIN EN 60664-1
• Low rated power consumption
• 2 changeover contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
• Adjustment to customers specification
• Compact size, small height (at horizontal model)
• OA 5661.12 horizontal mounting
• OA 5662.12 vertical mounting
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:6 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,4 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 70 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:37 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661.12
• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching safety because of gold plated double contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• Voltage range 0.75 ... 1.2 UN
• 15.5 mm height
Function:Safety relays with double contacts
Type of relay:monostabil
Contact material:AgNi + 5 µm Au
Continuous current:5 A
Nominal voltage UN DC:6 - 110 V
Voltage Range UN:0,75 - 1,2 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:5,5 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT III (wash-tight)
Size L x W x H:46,5 x 22 x 15,5 mm
Approvals:TÜV; cRUus
Relay type:OA 5621_D