In measurement and control technology digital indicators are used to constitute measured values or process variables.
Name:Indicator
Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V
Input impedance:>10 MΩ, Pt100 measuring current: 175µA, 0…20 mA: 100 Ω, 0…5 V: >1 MΩ
Temperature measuring range:-130 to 800 °C, Pt100: -200…+850 °C, mV, V, mA: Linear, adjustable range: -31000 to +31000
Accuracy:depends on input, see data sheet
Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou
Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types)
A/D converter resolution:128000 levels, display: 62000 levels
Power supply:100...240 V AC ± 10%, 50…60 Hz
Display:1-row, 5-digit LED-dispay, red
Environmental conditions:Interior, 0...+55 °C, 20...85% RH
Protection category:IP65 at front wall (by correct installation)
Dimensions:(LxWxH) 96 x 92 x 48 mm ( Installation depth 87 mm)
Weight:0.15 kg
In measurement and control technology digital indicators are used to constitute measured values or process variables.
Name:Indicator
Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V
Input impedance:>10 MΩ, Pt100 measuring current: 175µA, 0…20 mA: 100 Ω, 0…5 V: >1 MΩ
Temperature measuring range:-130 to 800 °C, Pt100: -200…+850 °C, mV, V, mA: Linear, adjustable range: -31000 to +31000
Accuracy:depends on input, see data sheet
Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou
Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types)
A/D converter resolution:128000 levels, display: 62000 levels
Power supply:100...240 V AC ± 10%, 50…60 Hz
Display:1-row, 5-digit LED-dispay, red
Environmental conditions:Interior, 0...+55 °C, 20...85% RH
Protection category:IP65 at front wall (by correct installation)
Dimensions:(LxWxH) 96 x 92 x 48 mm ( Installation depth 87 mm)
Weight:0.15 kg
In measurement and control technology digital indicators are used to constitute measured values or process variables.
Name:Controller
Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V
Input impedance:10 MΩ; 4...20 mA,; 100 Ω; Pt100 Measuring current: 175 µA
Temperature measuring range:-270…+1800 °C, Pt100: -200…+850 ºC, 0…50 mV: Linear, adjustable range: -1999 bis 9999
Accuracy:depends on input, see data sheet
Output:Logic output for SSR, O/N contact SPST relay 3 A / 230 V AC
Measuring rate:55/s
A/D converter resolution:Display 12000 Levels from -1999 to 9999
Power supply:100...240 V AC (±10%), 50…60 Hz
Display:2-row, 4-digit LED-Dispay, red and green
Environmental conditions:0...+60 °C
Protection category:IP65 at front wall (by correct installation)
Dimensions:(LxWxH) 100 x 48 x 48 mm Switchboard detail 45.5 x 45.5 mm, installation depth 97 mm)
Weight:0.15 kg