Termékek mr1100 100eus (11)

MK 10

MK 10

Modern thermal transfer printer for Partex PO-profiles. Print Thermal transfer printing: 300 dpi print resolution. Printing speed: 125 mm/s. Temperature range Operating temperature: +10°C to +35°C Humidity: 30 - 85 % not condensing To obtain the best printing result, the temperature of the profile shouldn’t be lower then +25°C. Measurements: (L x W x H): 446 x 242 x 275mm
KS-QN 901

KS-QN 901

Ein besonderes Feature ist hierbei der Monitor, auf dem bis zu vier Kameras abwechselnd oder gleichzeitig angezeigt werden können.
MALTO 95

MALTO 95

MALTO 95 mit speziellem Maltodextrin von FREY Nutrition bestellen. Dextroseäquivalent von 12 für maximale Glykogenauffüllung und Muskelaufbau.
Univerzális Jelző N1500 - Jelzők és vezérlők

Univerzális Jelző N1500 - Jelzők és vezérlők

In measurement and control technology digital indicators are used to constitute measured values or process variables. Name:Indicator Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V Input impedance:>10 MΩ, Pt100 measuring current: 175µA, 0…20 mA: 100 Ω, 0…5 V: >1 MΩ Temperature measuring range:-130 to 800 °C, Pt100: -200…+850 °C, mV, V, mA: Linear, adjustable range: -31000 to +31000 Accuracy:depends on input, see data sheet Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types) A/D converter resolution:128000 levels, display: 62000 levels Power supply:100...240 V AC ± 10%, 50…60 Hz Display:1-row, 5-digit LED-dispay, red Environmental conditions:Interior, 0...+55 °C, 20...85% RH Protection category:IP65 at front wall (by correct installation) Dimensions:(LxWxH) 96 x 92 x 48 mm ( Installation depth 87 mm) Weight:0.15 kg
MICRO 850/1000

MICRO 850/1000

Mit der Senkrechtmarkise MICRO 850/1000 werten sie ihre Fassade, ihren Wintergarten oder ihr Glasdach gleich mehrfach auf perfekter Sonnen- und Blendschutz, hoch wertige Raumdekoration, eine ganz besondere Lichtatmosphäre – und der Blick nach draußen ist trotzdem weiter möglich. Die MICRO 850/1000 wurde speziell für den einsatz im Wintergarten-, Fenster- und Loggiabereich entwickelt. Sie ist mit seitlicher Schienenführung und einer kompakten Kassette ausgestattet, die im geschlossenen Zustand einen optimalen Schutz für das Tuch bietet. Entscheiden Sie sich nach Zweck und Geschmack für offene oder geschlossene seitliche Führung.
TMS-150 TopMap Metro

TMS-150 TopMap Metro

Das TMS-150 TopMap Metro.Lab von Polytec ist ein hochpräzises Weißlicht-Interferometer (Coherence Scanning Interferometer) mit einem großen vertikalen Verfahrweg
Maxi MR 1 Digitális

Maxi MR 1 Digitális

Magnetrührer ohne Heizung Leistungsstarke Magnetrührer ohne Heizung. - Flaches, standfestes Edelstahlgehäuse - Blockierfester Motor - Drehzahl stufenlos einstellbar - Digitale LED-Drehzahlanzeige - Zeitschaltuhr 0 - 56 min mit Dauerschaltung - Rührmenge (H2O) bis 150 Liter
Univerzális Jelző N1500 - Hőmérsékletmérő eszközök

Univerzális Jelző N1500 - Hőmérsékletmérő eszközök

In measurement and control technology digital indicators are used to constitute measured values or process variables. Name:Indicator Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V Input impedance:>10 MΩ, Pt100 measuring current: 175µA, 0…20 mA: 100 Ω, 0…5 V: >1 MΩ Temperature measuring range:-130 to 800 °C, Pt100: -200…+850 °C, mV, V, mA: Linear, adjustable range: -31000 to +31000 Accuracy:depends on input, see data sheet Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types) A/D converter resolution:128000 levels, display: 62000 levels Power supply:100...240 V AC ± 10%, 50…60 Hz Display:1-row, 5-digit LED-dispay, red Environmental conditions:Interior, 0...+55 °C, 20...85% RH Protection category:IP65 at front wall (by correct installation) Dimensions:(LxWxH) 96 x 92 x 48 mm ( Installation depth 87 mm) Weight:0.15 kg
Vezérlő N1020 - Jelzők és vezérlők

Vezérlő N1020 - Jelzők és vezérlők

In measurement and control technology digital indicators are used to constitute measured values or process variables. Name:Controller Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V Input impedance:10 MΩ; 4...20 mA,; 100 Ω; Pt100 Measuring current: 175 µA Temperature measuring range:-270…+1800 °C, Pt100: -200…+850 ºC, 0…50 mV: Linear, adjustable range: -1999 bis 9999 Accuracy:depends on input, see data sheet Output:Logic output for SSR, O/N contact SPST relay 3 A / 230 V AC Measuring rate:55/s A/D converter resolution:Display 12000 Levels from -1999 to 9999 Power supply:100...240 V AC (±10%), 50…60 Hz Display:2-row, 4-digit LED-Dispay, red and green Environmental conditions:0...+60 °C Protection category:IP65 at front wall (by correct installation) Dimensions:(LxWxH) 100 x 48 x 48 mm Switchboard detail 45.5 x 45.5 mm, installation depth 97 mm) Weight:0.15 kg
ALMATreat KK1000

ALMATreat KK1000

Kombiprodukt (Korrosionsschutz für Fe-Metalle & Buntmetalle, Härtestabilisator und Dispergator) für halboffene oder geschlossene Kühlkreisläufe
VL 50

VL 50

The desktop laser welding machine delivers with 50 watts good beam power and is characterized by its uniform, powerful, yet soft welding behaviour. The manual welding laser VL 50 has a very spacious working chamber and allows to weld precious metals such as silver and gold due to its powerful laser behaviour. Longer concentrated work is easily possible thanks to the ergonomically designed housing with the well thought-out arrangement of keyboard, display and joystick. The desktop laser VL 50 is a valued tool in the manufacture and repair of dentures and jewelry, in welding on precision parts, medical technology components and sensors, but also when applying materials to small molds.