In measurement and control technology digital indicators are used to constitute measured values or process variables.
Name:Indicator
Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V
Input impedance:>10 MΩ, Pt100 measuring current: 175µA, 0…20 mA: 100 Ω, 0…5 V: >1 MΩ
Temperature measuring range:-130 to 800 °C, Pt100: -200…+850 °C, mV, V, mA: Linear, adjustable range: -31000 to +31000
Accuracy:depends on input, see data sheet
Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou
Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types)
A/D converter resolution:128000 levels, display: 62000 levels
Power supply:100...240 V AC ± 10%, 50…60 Hz
Display:1-row, 5-digit LED-dispay, red
Environmental conditions:Interior, 0...+55 °C, 20...85% RH
Protection category:IP65 at front wall (by correct installation)
Dimensions:(LxWxH) 96 x 92 x 48 mm ( Installation depth 87 mm)
Weight:0.15 kg
Tronzadora de un cabezal con movimiento manual o automático
de la cuchilla hacia abajo.
Mesa giratoria.
Inclinación del cabezal de 90° a 45° Sx (eje Y).
Dispositivo de bloqueo manual en cualquier ángulo intermedio.
Especificaciones técnicas: diámetro de la cuchilla 400mm,
lubricación neumática, descenso manual de la unidad,
inclinación manual del cabezal (eje Y), rotación manual del
cabezal, grados intermedios en manual, pinzas neumáticas.
100% Acrylic water based paint. Perfect leveling. Fine finished and large decorative beauty. Antisplashed. High spreading rate. Extreme rub resistance. Plaster ceilings and walls, plastered walls and masonry in general.
Paint with protection against fungus and algae.
In measurement and control technology digital indicators are used to constitute measured values or process variables.
Name:Indicator
Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V
Input impedance:>10 MΩ, Pt100 measuring current: 175µA, 0…20 mA: 100 Ω, 0…5 V: >1 MΩ
Temperature measuring range:-130 to 800 °C, Pt100: -200…+850 °C, mV, V, mA: Linear, adjustable range: -31000 to +31000
Accuracy:depends on input, see data sheet
Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou
Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types)
A/D converter resolution:128000 levels, display: 62000 levels
Power supply:100...240 V AC ± 10%, 50…60 Hz
Display:1-row, 5-digit LED-dispay, red
Environmental conditions:Interior, 0...+55 °C, 20...85% RH
Protection category:IP65 at front wall (by correct installation)
Dimensions:(LxWxH) 96 x 92 x 48 mm ( Installation depth 87 mm)
Weight:0.15 kg
In measurement and control technology digital indicators are used to constitute measured values or process variables.
Name:Controller
Input:Thermocouple Type J,K,E,N,R,S,T; Pt100 in 3-wire technique; 4...20 mA; 0...50 mV; 0...10 V
Input impedance:10 MΩ; 4...20 mA,; 100 Ω; Pt100 Measuring current: 175 µA
Temperature measuring range:-270…+1800 °C, Pt100: -200…+850 ºC, 0…50 mV: Linear, adjustable range: -1999 bis 9999
Accuracy:depends on input, see data sheet
Output:Logic output for SSR, O/N contact SPST relay 3 A / 230 V AC
Measuring rate:55/s
A/D converter resolution:Display 12000 Levels from -1999 to 9999
Power supply:100...240 V AC (±10%), 50…60 Hz
Display:2-row, 4-digit LED-Dispay, red and green
Environmental conditions:0...+60 °C
Protection category:IP65 at front wall (by correct installation)
Dimensions:(LxWxH) 100 x 48 x 48 mm Switchboard detail 45.5 x 45.5 mm, installation depth 97 mm)
Weight:0.15 kg