Termékek prima keleti s p (5)

Fali tűzcsap ajtó EI 60 - tűzcsap

Fali tűzcsap ajtó EI 60 - tűzcsap

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Kereskedelmi teljesítmény elemzése - Stratégia és kereskedelmi teljesítmény

Kereskedelmi teljesítmény elemzése - Stratégia és kereskedelmi teljesítmény

Nous réalisons une analyse approfondie de votre département commercial pour identifier les forces et les faiblesses, les opportunités et les défis. Nous évaluons vos processus de vente, votre gestion des leads, vos techniques de négociation, etc.
Hordozható Fúrók - Partnerünk ELSA - Fúrók

Hordozható Fúrók - Partnerünk ELSA - Fúrók

Pour accéder au site ELSA, cliquez ci- après
Fali tűzcsap ajtó 120 MN - tűzcsap

Fali tűzcsap ajtó 120 MN - tűzcsap

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Függőleges tűzcsapda ajtó 60 PERC - tűzcsapda

Függőleges tűzcsapda ajtó 60 PERC - tűzcsapda

Frame made of aluminium profile bars connected by "Tox" connections - Intumescent gas, smoke and flame tight seal in case of fire - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards - Quick and easy installation The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.