Termékek futon (2)

FUTÓVONAL TENSIOMÉTEREK - Tensiométerek

FUTÓVONAL TENSIOMÉTEREK - Tensiométerek

Load cells specially designed to measure the tension force applied to a running cable or running rope. o Custommade design according to your needs type of rope (steel, synthetic, optical fiber, umbilical) capacity rope diameter (from 6 up to 115 mm) maximum winding speed accuracy Material load pin stainless steel other nickelplated steel or stainless steel (option) o Complete range of CE certified electronics and load limitation devices available Reference:5570-5575 Protection class:IP65 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
FUTÓVONALI TENSIOMÉTEREK LEVEHETŐ KÖZÉPSŐ KEREKETT - Tensiométerek

FUTÓVONALI TENSIOMÉTEREK LEVEHETŐ KÖZÉPSŐ KEREKETT - Tensiométerek

Load cells specially designed to measure the tension force applied to a running wire rope. The removable center sheave enables easy installation without cutting the winch lines. o Wide range of cables (Ø from 6 up to 115 mm) other components stainless steel (5580) other components nickelplated steel (5585) o Complete range of CE certified electronics and load limitation devices available o Custommade manufacturing Reference:5580 - 5585 Protection class:IP67 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70