As pharmaceutical architecture becomes increasingly complex, so does its sensitivity to oxygen and contamination. EVALâ„¢provides superior oxygen and chemical barriers that offer safe and transparent alternatives to PAN, PVDC and aluminium foil. Â
Add EVALâ„¢ barrier to a wide range of packaging options from pouches, SUP and overwrap to bottles to formed push-through packs. For the most sensitive applications, unique oxygen scavenging EVALâ„¢, adds extra safety and extends shelf life by reducing oxygen ingress to zero.
High Quality Type IIR Surgical Mask/ Medical Mask, Ready Stock in Belgium. Used for for all kinds of clinical personnel in non-sterile operation and non-invasive operation process wear. Covers the users mouth, nose and jaw.
Air purification unit for cleaning room air
The Pro air purification unit cleans the air inside the room. The Pro unit is used for the protection of vulnerable (immune-compromised) patients, protection against infectious patients, the elimination of aspergillus during renovation works, and for the upgrading of air quality in operating theatres, ICUs, isolation rooms.
The Pro unit gives immediate results (within 20 minutes max) and once deployed maintains integrity of the air quality at all times.
The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.
EVAL's largest use world-wide is for food packaging. Since 1972, EVALâ„¢ has helped reduce food waste by blocking oxygen ingress and contaminants, extending shelf life and avoiding product waste.
EVAL provides the functional gas and contamination barrier to the entire structure. The result has often been a reduction in packaging waste by reducing the weight and amount of packaging materials used, without compromising on function. Â
EVAL barrier properties avoid vitamin and fat oxidation, extending shelf life of parenteral nutrition. Compared to standard plastic packaging, additive content can be guaranteed for longer, even while reducing the necessary doses.
EVAL barrier can be added to many different types of light weight, unbreakable and halogen-free all-plastic packaging, improving safety in use and reducing environmental impact.
As product formulas become more complex, they often become more volatile andsensitive to oxygen.
EVALâ„¢ provides a functional barrier in both directions: assuring formula integrity and quality while blocking the permeation of external gases and contaminants.
Unbreakable all-plastic barrier structures with EVALâ„¢ allow transparencyand squeezability for safe and convenient use.
In addition to flexible pouches and SUP, typical applications inlcude ampoules, bottles, eye liquid dosers and inhalers.
In addition to oxygen and CO 2 gas barrier, EVAL™ provides an outstanding odour barrier, especially useful for ostomy applications.
EVAL™’s functional barrier works in both directions, protecting contents against contamination while keeping them from escaping into the environment.
Flexible barrier structures provide an efficient disposable solution for biomanufacturing. When incinerated, the tiny but functional amounts of EVALâ„¢ in the structure release only CO 2 and water vapour. Â No dioxin, no metal residue.
EVAL is already used world-wide to improve the safety, shelf life and process efficiency of packaging for baby food and other infant formulas.
With a reliable performance, shelf-stable packaging can be designed to safely limit the total amount of oxygen ingress. Quality is assured and shelf life is extended, notably by protecting fat and vitamin content against oxidation.
Additional safety and extended shelf life with oxygen scavenger
For the most oxygen-sensitive products, EVALâ„¢ grades with oxygen scavenging capacity can create a negative oxygen increase, providing extra safety margins and extending product shelf life.
EVAL offers a reliable alternative to aluminium foil, with excellent stress crack and pinhole resistance. Multilayer barrier films with EVALâ„¢ can be laminated onto a varietyof different substrates to provide sachets with functional barrier.
Sealable and anti-scalping
Specific grades of EVALâ„¢ film can be laminated to a substrate, providing the sachet or pouch with both barrier properties and a sealable internal contact layer with excellent anti-scalping properties.
Pre-filtration filters on the outside of the unit
Indoor work leads to an increased concentration of aspergillus. In order to protect the high effiency particulate air filter inside the unit during building activities, pre-filtration frames with filters are added to the outside of the device.
The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.
Combi 1.1
– Innovating product
– Better and cheaper than Laminar Flow
– Adjustable Air Nozzles for perfect airflow
– Creates high efficiency Cleanroom Class ISO6 or even ISO5
– Installation: 1 day max.
– Results within 30 minutes
– Clean Air Capacity: 800 m3/hour maximum, with 1/4 of fresh air (optional)
– Only needs W 90 cm x H 154 cm x D 34 cm of wall space
– Quiet operating level
– Max. distance between inside & outside unit: 25 meter
To protect immune compromised patients
To upgrade ICU’s, laboratories and O.T’s
Note
Pressure difference depends on air tightness of the room. For information and advice contact MedicCleanAir.
Isolation Unit, 1-piece, for positive or negative room pressure
This Isolation Unit is made for installation in suspended or false ceilings, and walls.
Can be connected to an existing ventilation system or new tube system. Reccommended for installations were the point of extraction and supply are further away from eachother.
Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal).
Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured.
– Automatic differential pressure regulation
– Automatic pressure loss alert
– Filter detection by ID code (filter condition)
– Complies with CDC guidelines (Centres for Disease Control and Prevention)
Used in hospitals, clinics and medical facilities Immune-compromised patients
Oncology, haematology, neonato
Isolation Unit, 2-piece, for positive or negative room pressure
This Isolation Unit is made for installation on walls or windows. Pressure differences up to 20 Pascal are easily generated.
Negative pressure is obtained when the filter unit is placed inside the room, and the ventilator unit is placed outside the room. (infectious patients) Positive pressure is obtained when the ventilator unit is placed inside the room and the filter unit is placed outside the room. (immune-compromised patients).
Both parts are connected by a tube – through the wall – which contains an air back-pressure flap (standard) and fire damper (optional). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured.
– Automatic differential pressure regulation
– Automatic pressure loss alert
– Filter detection by ID code (filter condition)
– Complies with CDC guidelines (Centres for Disease Control and Prevention)
Isolation Unit, 1-piece, for positive or negative room pressure
This Isolation Unit is made for installation in suspended or false ceilings, and walls.
Can be connected to an existing ventilation system or new tube system. Reccommended for isolation rooms up to 40m2 / 120m3.
Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal).
Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured.
ISO520 can be used with Remote Control RC100 or RC200.
Remote controllers with key switches or with key switches and screen-displays for permanent 100 % security, used with all MedicCleanAir units.
Remote controller RC 200 with key switches and screen-displays
Integrated function keys for selecting mode.
Constant pressure difference display.
Illuminated display for operating data recognition.
Key switch for secure functional change.
Secure operation by qualified personnel only.
Choice of incremental speed option.
Setting for required pressure difference (automatic at Step 4 with ISO unit).
Choice of filter test duration (for PRO air purification unit at level 4).
Alarm function (visual and acoustic) for pressure difference.
Alarm function (visual and acoustic) for filter condition.
Remote controllers with key switches or with key switches and screen-displays for permanent 100 % security, used with all MedicCleanAir units.
Remote controller RC 100 with key switches
Key switch to select speed.
Connects directly to the air purification unit or isolation unit / no seperate power supply needed.
Avoids undesirable external use (only hospital staff)
Air purification unit for cleaning room air
The Pro air purification unit cleans the air inside the room. The Pro unit is used for the protection of vulnerable (immune-compromised) patients, protection against infectious patients, the elimination of aspergillus during renovation works, and for the upgrading of air quality in operating theatres, ICUs, isolation rooms.
The Pro unit gives immediate results (within 20 minutes max) and once deployed maintains integrity of the air quality at all times.
Pre-filtration filters on the outside of the unit
Indoor work leads to an increased concentration of aspergillus. In order to protect the high effiency particulate air filter inside the unit during building activities, pre-filtration frames with filters are added to the outside of the device.
The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.