Load cells specially designed to measure the tension force applied to a running cable or running rope.
o Custommade design according to your needs
type of rope (steel, synthetic, optical fiber, umbilical)
capacity
rope diameter (from 6 up to 115 mm)
maximum winding speed
accuracy
Material
load pin stainless steel
other nickelplated steel or stainless steel (option)
o Complete range of CE certified electronics and load limitation devices available
Reference:5570-5575
Protection class:IP65
Cable length:6 m (other lengths available on request)
Reference temperature (°C):23
Compensated temperature range (°C):-10...+45
Service temperature range (°C):-25...+70
Storage temperature range (°C):-50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1
Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1
Nominal sensitivity (mV/V):± 1
Input resistance (ohm(s)):350 ± 2
Output resistance (ohm(s)):350 ± 2
Insulation resistance (50 V) (Mohm(s)):> 5000
Reference excitation voltage (VDC):10
Permissible nominal range of excitation voltage (VDC):3...12
Safe load limit (% F.S.*):200
Breaking load (% F.S.*):> 300
Permissible dynamic loading (% F.S.*):70
Load cells specially designed to measure the tension force applied to a running wire rope. The removable center sheave enables easy installation without cutting the winch lines.
o Wide range of cables (Ø from 6 up to 115 mm)
other components stainless steel (5580)
other components nickelplated steel (5585)
o Complete range of CE certified electronics and load limitation devices available
o Custommade manufacturing
Reference:5580 - 5585
Protection class:IP67
Cable length:6 m (other lengths available on request)
Reference temperature (°C):23
Compensated temperature range (°C):-10...+45
Service temperature range (°C):-25...+70
Storage temperature range (°C):-50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1
Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1
Nominal sensitivity (mV/V):± 1
Input resistance (ohm(s)):350 ± 2
Output resistance (ohm(s)):350 ± 2
Insulation resistance (50 V) (Mohm(s)):> 5000
Reference excitation voltage (VDC):10
Permissible nominal range of excitation voltage (VDC):3...12
Safe load limit (% F.S.*):200
Breaking load (% F.S.*):> 300
Permissible dynamic loading (% F.S.*):70